AC FLEXIBLE CURRENT SENSOR CT7040 series

Flexible 600A/6000A AC Current Sensors in 3 Sizes

Hioki clamp sensors are best-in-class measuring devices incorporating
Hioki’s expertise in current sensing technology. The CT7040 Series
compromise of 600A/6000A AC flexible current sensors in three
different loop sizes that pair with the detachable Display Unit to
measure large currents in crowded wiring and confined spaces.

Model No. (Order Code)

CT70466000 A, φ254 mm (10.00 in)
CT70456000 A, φ180 mm (7.09 in)
CT70466000 A, φ100 mm (3.94 in)
GOOD DESIGNCE
 

Note: CT7040 series cannot be used alone.
Use with the Display Unit CM7290,
CM7291 to connect with Data Loggers and Memory HiCorders.
When used in combination with CM7290 or CM7291,
the frequency band of current display
and waveform output becomes narrow.

CAT IV 600 V, CAT III 1000 V
Key Features

• Ideal for use in environmental testing with broad -40˚C to 85˚C temperature range
• High precision with a clamp-type design, ±0.3% amplitude accuracy, ±0.1° phase accuracy
• Wide-bandwidth from DC to 20 kHz
• Single-handed operation and robust locking mechanism
• Reduced effects from magnetic fields, conductor position, and noise from nearby wires
• For EV/HEV battery charge and discharge efficiency testing and inverter and power conditioner conversion efficiency evaluations

A comment from the Good Design Award 2016

“I was impressed with the high level of functionality combined with a compact design and a dustproof and waterproof enclosure as well as the high level of technical skill evident in the integration of multiple types of plastic and two cables. These appealing products also exhibit beautiful finish quality.”


Connect to Recorders, Data loggers, and Oscilloscopes

The CT7000 series cannot be used alone. Use with the Display Unit CM7290, CM7291 to connect with Data Loggers and Memory HiCorders.

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
* It is waterproof to maintain measurement function, and measuring the live part in wet condition increases the risk of electric shock.

 CT7046CT7045CT7044
Rated measurement current6000 A AC
Internal Measurement range600A AC/ 6000A AC (Range is controlled by main device)
Max. allowable input10000 A continuous (at 6000 A range, 45 to 66 Hz, requires derating )
Bandwidth10 Hz to 50 kHz (±3dB)
(When used in combination with CM7290 or CM7291: 10 Hz to 1 kHz)
Amplitude and phase accuracy±1.5 % rdg. ±0.25 % f.s. (f.s. is internal range, 45 to 66 Hz) ±1 deg
Output rate1 mV/A (600 A*), 0.1 mV/A (6000 A)
*Selectable only when used with CM7290, CM7291, PQ3100
Max. rated voltage to earthAC 600 V (CAT IV), AC 1000 V (CAT III)
Loop diameterφ 254 mm (10.00 in) or lessφ 180 mm (7.09 in) or lessφ 100 mm (3.94 in) or less
Dust and water resistance *IP54 (when connected to a supported instrument, Do not make measurements when wet.)
Output connectorsHIOKI PL 14
Operating temperature range-25 °C to 65 °C (-13 °F to 149 °F)
DimensionsFlexible loop cable diameter: φ7.4 mm (0.29 in), Cable length: Between flexible loop and battery box: 2.3 m (7.55 ft), Output cable: 20 cm (0.66 ft), Battery box25 mm (0.98 in)W × 72 mm (2.83 in)H × 20 mm (0.79 in)D
Mass186 g (6.6 oz)174 g (6.1 oz)160 g (5.6 oz)
AccessoriesInstruction manual ×1
Catalog: AC/DC CURRENT SENSOR CT7000 Series, DISPLAY UNIT CM7290, CM7291Download PDF  [4MB]English

For more information, click here

-->