AC FLEXIBLE CURRENT SENSOR CT9667

Easy to Loop Around, Even in Confined Spaces

Hioki current sensors are best-in-class devices for use with power
meters, PQAs and Memory HiCorders. The CT9667 series are flexible
Rogowski type AC sensors comprising of 3 different models in various
loop diameter sizes from 100 to 254 mm. The 100mm and 180mm diameter
sensor also feature extra thin cables for easier looping around
complicated wiring. All 3 sensors 500A/5000A ranges, making them
ideal for measuring large load current.

Model No. (Order Code)

CT9667-01φ100 mm (3.94 in)
CT9667-02φ180 mm (7.09 in)
CT9667-03φ254 mm (10.00 in)
CE
 

Note: These current sensors may also be used
with HIOKI power quality analyzers, power meters
or Memory HiCorders.

CAT IV 600 V, CAT III 1000 V
Key Features

• Thinner cables are easy to use in confined spaces and with complicated wiring (-01, -02)
• Shaped so that it’s easy to route through complex wiring
• Easily supports large current measurements up to 5000 A
• Wide 10 Hz to 20 kHz band with excellent frequency characteristics
• Choose from three conductor diameter sizes
• Combine with Hioki power meters or Memory HiCorders (with BNC input terminals)

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

 CT9667-01CT9667-02CT9667-03
Rated input current5000 A AC/ 500 A AC
Max. allowable input10000 A continuous (45 to 66 Hz, requires derating at frequency)
Bandwidth10 Hz to 20 kHz (±3dB)
Amplitude and phase accuracy±2 % rdg. ±0.3 % f.s. (45 to 66 Hz, at center of flexible loop)
Phase: ±1 deg (45 to 66 Hz)
Output voltage500 mV AC/f.s. (0.1 mV AC/A) at 5000 A range
500 mV AC/f.s. (1 mV AC/A) at 500 A range
Max. rated voltage to earth1000 V AC (CAT III), 600 V AC (CAT IV)
Core diameterφ 100 mm (3.94 in)φ 180 mm (7.09 in)φ 254 mm (10.00 in)
Output terminalBNC
Operating temperature-25 °C to +65 °C
(-13 °F to 149 °F)
-25 °C to +65 °C
(-13 °F to 149 °F)
-10 °C to +50 °C
(14 °F to 122 °F)
Power supplyLR6 (AA) alkaline batteries ×2, Continuous use : 7 days (rated power 35 mVA), or AC adapter 9445-02/-03 (rated power 0.2 VA), or External power supply 5 to 15 V DC (rated power 0.2 VA)
Dust and water resistanceFlexible loop only: IP54
* Do not use when wet.
N/A
Dimensions and massFlexible loop cable diameter: φ7.4 mm (0.29 in),
Cable length: Between flexible loop and battery box: 2 m (6.56 ft),
Output cable: 1 m (3.28 ft), Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 280 g (9.9 oz)
Flexible loop cable diameter: φ13 mm (0.51 in), Cable length: Between flexible loop and battery box: 2 m (6.56 ft), Output cable: 1 m (3.28 ft)
Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 470 g (16.6 oz)
AccessoriesLR6 (AA) alkaline batteries ×2, Instruction manual ×1