CLAMP ON POWER HiTESTER 3169
Demand Measurement up to 4 Circuits and
Simultaneous Harmonics Analysis
Hioki portable power meters and analyzers are best in class power
measuring instruments for measuring single to three-phase lines
with a high degree of precision and accuracy. The 3169 is clamp
on power meters designed to measure demand and harmonics, which
are important for energy management, as well as basic electrical
parameters such as voltage, current, power, power factor, and
integrated power (watthours).

Model No. (Order Code)

3169-20Main unit, clamp sensor is sold separately
3169-21With D/A output function model
RS232CTrueRMSCE
 

Note: Optional current sensor is necessary to measure current
or power parameters. To store measurement data, use only
the guaranteed PC cards sold by Hioki.

Key Features

• Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits
• Data can be saved onto a PC card
• High-speed and continuous processing to measure individual waveforms
• High-speed D/A output for analog graph recording (Model 3169-21)

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement line & number of circuitsSingle-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit)
Note: 50 or 60 Hz, and that share the same voltage line
Measurement itemsVoltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value (up to 40th order)
Measurement range[Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
Basic accuracyAC Voltage: ±0.2 % rdg. ±0.1 % f.s.
AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)
Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models)
Measurement methodDigital sampling, PLL synchronization or 50/60 Hz fixed clock
Display refresh rate2 times /sec (except when a PC card accessing, or RS-232C communications)
Data save intervalStandard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
Frequency characteristicsFundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform)
Other functionsError connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.)
Power supply100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions and mass210 mm (8.27 in)W × 160 mm (6.30 in)H × 60 mm (2.36 in)D, 1.2 kg (42.3 oz)
AccessoriesVoltage cord L9438-53 ×1 (Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4), Power cord ×1, Instruction manual ×1, Quick start manual ×1, CD-R ×1 (RS-232C interface operating manual) ×1, Input cord label ×1, Connection cable 9441 ×1 (for the 3169-21 only)
Catalog: CLAMP ON POWER HiTESTER 3169Download PDF  [1MB]English

For more information, click here

-->