CURRENT PROBE CT6710
Capture Inrush, Micro and High-Speed Currents with a
Single Probe
Hioki flat bandwidth current probes are best-in-class current sensors
for use with Memory HiCorders and high performance oscilloscopes. The
CT6710 is a 3-range, high-sensitivity current probe that offers a wide
DC to 50 MHz bandwidth and 200 μA to 30 A input, letting your capture
signals across an expansive current range, from steady state to
transient currents, when developing switching power supplies, inverters,
and motor controllers.

Model No. (Order Code)

CT6710From 200μA, 50MHz bandwidth

CEDC

Note: If power cannot be supplied from the
Memory HiCorder, the optional Power Supply
3269 is required. Please pay attention to
offset drift during continuous, long-term
measurement.

 

Key Features

• 3 ranges in a single probe - 30 A, 5 A, 0.5 A. Observe a wide current range from micro currents to 30 A.
• Wide band: DC to 50 MHz (-3 dB)
• High S/N ratio and 10 times output rate: Observe waveforms at 100 μA/div at oscilloscope maximum voltage sensitivity setting of 1 mV/div
• Directly connect to an oscilloscope’s BNC input terminal *1
• Also available: CT6711 Current Probe with DC to 120 MHz bandwidth

*1 Connecting the probe's metal BNC terminal to a Memory HiCorder’s plastic BNC terminal may damage the plastic terminal or cause it to become misshapen. To avoid damage, please position the probe cable perpendicular to the recorder before detaching it from the terminal.


3 Full Ranges of 30 A, 5 A, And 0.5 A Deliver an Expansive Current Measurement Spectrum

Monitor current under a broad range of operating conditions from 0.5 to 30A.
Simply press the RANGE key on the termination box to toggle between ranges,
and analyze everything from sudden inrush to slow moving consumption current,
down to micro currents of low energy devices, all with a single device.

Built-in Function to Protect Against Excessive Input

When input exceeds the rated value, a warning indicator flashes to signal a warning.
In addition, if you select the incorrect range and then input a current
signal that is above the rated current for that range,
this function protects the instrument from damage due to overheating.
Caution: Input currents that exceed the frequency derating for the 30 A
range may cause measurement circuit damage before the protection
function kicks in.

High Signal-to-Noise (S/N) Ratio

Observe waveforms as they are without needing to rely on your oscilloscope’s filter
settings and averaging function. The 10V/A output rate is 10 times the
traditional 1V/A rate of legacy products, allowing you to improve the
oscilloscope’s voltage sensitivity by a factor of 10, thereby enhancing
the S/N ratio of the scope itself to deliver much clearer waveforms.

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months)

Frequency bandwidthDC to 50 MHz (-3 dB)
Rise time7.0 ns or shorter
Delay time (Typical)30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns
(Delay time relative to rising waveform of input signal 1 ns)
Noise level75 μA rms max (at 0.5 A range, using 20 MHz band measuring instrument)
Max. rated current30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms
(DC, and sine wave, requires derating at frequency)
Max. allowable peak current30 A range: ±50 A peak (within the input limit time 2 s)
5 A range: ± 7.5 A peak,
0.5 A range: ± 0.75 A peak (< 10 MHz), ±0.3 A peak (≥ 10 MHz)
Amplitude accuracy30 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (≤ 10 Arms, DC, 45 to 66 Hz sine wave, within the maximum peak current of each range)
5 A range: ±3.0% rdg. ±1 mV, (Typical) ±1.0% rdg. ±1 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range)
0.5 A range: ±3.0% rdg. ±10 mV, (Typical) ±1.0% rdg. ±10 mV (DC, 45 to 66 Hz sine wave, within the maximum peak current of each range)
Output rate30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A, (The output of this probe is internally terminated, so connect to voltage input equipment with high input impedance such as 1MΩ)
Measurable conductorsφ 5 mm (0.20 in), Insulated conductor
Power supplySupplied from Power Supply 3269, Probe Power Unit Z5021
Cable lengthSensor cable (between relay box and sensor): 1.5 m (4.92 ft)
Power cable: 1.0 m (3.28 ft) (Power plug: FFA.0S.304.CLAC37Y / LEMO inc.)
Dimensions and massSensor: 155 mm (6.10 in)W × 18 mm (0.71 in)H × 26 mm (1.02 in)D, Relay box section: 45 mm (1.77 in)W × 120 mm (4.72 in)H × 25 mm (0.98 in)D
Terminator section: 29 mm (1.14 in)W × 83 mm (3.27 in)H × 40 mm (1.57 in)D mm, 370 g (13.1 oz)
AccessoriesInstruction manual ×1, Carrying case ×1
Catalog: CURRENT PROBE CT6710, CT6711Download PDF  [2MB]English

For more information, click here

-->