Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3542A delivers high-speed and high-stability measurements and improved productivity by minimizing variations and reducing contact errors. In addition, the low-impact measurement technology lets you measure resistance for miniature 008004-size electronic parts. | Model No. (Order Code)
Test fixtures are not supplied with the unit. |
---|
Key Features • Applied voltage limit function lets you switch the detection voltage to 5 V or less |
---|
Gently measure minuscule electronic components (0201 size) with functionality for limiting the applied voltage By limiting the voltage that is applied during measurement to 5 V or less, the RM3542A makes | |
Ensure reliable contact quickly with the contact improvement function The RM3542A improves contact with measurement specimens by eliminating oxide films and | |
Utilize a more evolved contact improvement function in low-power measurement The RM3542A allows contact improvement to be used in a broader range of situations, for | |
Use the scaling function to correct measurements as if the target component were mounted The RM3542A’s scaling function can correct for the difference in resistance values that |
Resistance range | [at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ resolution) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 16 steps [at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 6 steps |
---|---|
Display | Monochrome graphic LCD 240 × 64 dot, white LED backlight |
Measurement accuracy | [with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. (best case) |
Testing current | [at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC |
Open-terminal voltage | 20 V DC max. (with applied voltage limit function enabled: max. 10 V DC) |
Sampling rate | FAST, MEDIUM, SLOW, 3 settings |
Measurement times | [at 100 Ω /1000 Ω ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time) |
Integration time | 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) |
Other functions | Comparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), Applied Voltage Limit Function, Scaling Function, OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. |
Interfaces | RS-232C, Printer, GP-IB (Model RM3542-51) |
External I/O | Trigger, Hold input, Comparator output, Settings monitor terminal |
Power supply | 100 to 240 V AC, 50/60 Hz, 30 VA max. |
Dimensions and mass | 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz) |
Accessories | Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1 |
Catalog: RESISTANCE METER RM3542A, RM3542 | Download PDF [2MB] | English |
For more information, click here