Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8410-20 is an innovative wireless logging system capable of capturing up to 105 channels of data wirelessly using Bluetooth® wireless technology. | Model No. (Order Code)
The LR8410-20 alone is not capable of making measurements. |
SD Card bundled • Capture logging data using Bluetooth® wireless technology. Install logging modules in hard-to-reach locations (over line-of-sight distances of up to 30 meters *1 ) |
---|
Product Video
| |
A wireless data logger that supports a variety of measurements with a diverse line of measurement units For applications such as | |
A wireless data logger than can measure up to 105 channels of data Connect up to 7 measurement units to perform multipoint measurement across a maximum of 105 channels when using 15-channel units LR8510 or LR8511. Also pair with 1- or 2-channel wireless loggers, including LR8520, LR8512, LR8513, LR8514 or LR8515. Mix and match 7 types of measurement units to consolidate the measurements you need. Use Bluetooth(R) wireless technology to send and receive data over line-of-sight distances of up to 30 m. | |
Making the wiring process faster while minimizing costs - Wireless data logger ith a wired instrument… << Resolved with wireless data transmission >> The lack of wiring around the instrument makes for a clean installation. | |
Make measurements where it would not be practical to wire equipment directly - Wireless data logger With a wired instrument… << Resolved with wireless data transmission >> There’s no need to connect measurement units to the Wireless Logging Station LR8410 with long wires.
| |
Make measurements of interior conditions from the outside, with the door closed - Wireless data logger With a wired instrument… << Resolved with wireless data transmission >> Only the measurement unit needs to be installed in the vehicle.
| |
Test data from multiple locations can be managed along a single time axis. - Wireless data logger nstalling individual loggers on test equipment means each set of measured data is on its on time line, making it hard to compare the data with respect to a single time axis. Model LR8410 can observe measurement results from multiple pieces of experimental equipment as part of the same time series. Logging modules are small enough to fit almost anywhere.
| |
Ensure peace of mind even in the event of a signal disruption - backup functionEnsure peace of mind even in the event of a signal disruption - backup function Measurement units and wireless loggers have built-in buffer memory so that measurement data can be saved if communication is temporarily disrupted.This data is resent once communication is restored, allowing the measurement data to be stored in the Wireless Logging Station.
| |
Easy wireless setupThe LR8410 features Hioki’s Quick Set function. Since measurement units can be registered simply by following the Unit Registration Guide, even first-time users can start measurement right away. If no logging modules have been registered, the Quick Set screen is displayed when the LR8410 is turned on, and the instrument automatically detects any logging modules that are within communications range. It’s also easy to configure settings when adding measurement units later.
| |
Get results from the job site in real-time, GENNECT CROSS SF4000 Capture data on the PC while testing remotely |
No. of measurement channels | Max. 105 ch (use 7 units of LR8510 or LR8511) One or more LR8510 or LR8511 measurement modules are required. Main unit can control up to 7 modules with Bluetooth® wireless technology, mix and match modules as needed |
---|---|
Pulse, digital input | [Pulse totalization] [Rotation count] Not available |
Recording intervals | 100 ms(*2), 200 ms to 1 hour, 16 selections (All input channels are scanned within each recording interval.) (*2) Setting not available when the thermocouple burnout detection setting is on |
Data storage | Internal memory: 8 M-words, Data storage media: SD memory card or USB memory stick (Only data recorded to a genuine HIOKI SD memory card is guaranteed) |
Interface | LAN: 100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or E-mail system USB: USB 2.0 series mini-B receptacle ×1, Functions: Data acquisition using bundled software or PC commands, Transfer data from the SD memory card to a PC via USB drive mode |
Display device | 5.7 inch TFT color liquid crystal display (640 × 480 pixel) |
Functions | Save waveform data in real time to the SD memory card or USB memory stick, Numerical value calculations, Waveform calculations, 4ch alarm output (not isolated, common ground), and others |
Power supply | [AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 45 VA Max. (including AC adapter), 15 VA Max. (exclusive of AC adapter) [Internal battery] Using the Battery pack Z1007 (optional accessory), 3 hours of continuous use (at 23 ˚C reference data), 7 VA Max. [External power] 10 to 28 V DC, 15 VA Max. (Please contact your HIOKI distributor for connection cord) |
Dimensions and mass | 230 mm (9.06 in) W × 125 mm (4.92 in) H × 36 mm (1.42 in) D, 700 g (24.7 oz) (excluding Battery pack) |
Accessories | Instruction manual × 1, Measurement guide × 1, SD memory card (2GB) Z4001 × 1, CD-R (data collection software “Logger Utility”) × 1, USB cable × 1, AC Adapter Z1008 × 1 |
Compatible models | LabVIEW | MATLAB script |
---|---|---|
LR8410-20 | OK | N/A |
Wireless certification | Japan, United States, Canada, Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom, Thailand, Chile, and Mexico |
---|---|
Wireless certification (special) | Taiwan (Order Code: LR8410-20, LR8410-30 only) Australia, New Zealand (Order Code: LR8410-20 only) Singapore (Order Code: LR8410-20 only) China (Order Code: LR8410-30 only) Indonesia (Order Code: LR8410-20 only) UAE (Order Code: LR8410-20 only) |
Exempt from the wireless regulations | Viet Nam, Hong Kong, Macao, India, Russian Federation, Colombia, Pakistan, and Georgia |
Catalog: WIRELESS LOGGING STATION LR8410 | Download PDF [5MB] | English |
Catalog: WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515, LR8520 | Download PDF [3MB] | English |
Flyer Catalog: LR8410 Link | Download PDF [1MB] | English |
Catalog: GENNECT CROSS SF4000 | Download PDF [1MB] | English |
For more information, click here