1ms Sampling Portable Logger Expandable to 330 Channels with Your Choice of Plug-in or Wireless Input Modules
Your Personal 10-channel Logger
Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8450-01 offers 1ms sampling across up to 330 channels, and can be paired with 10 different types of plug-in or wireless input units. Collect data from wireless modules installed in remote or confined locations via a LAN connection. New input modules measure strain and distortion, ideal for automotive applications involving the evaluation of vehicle components as well as robotic equipment. Key Features | Model No. (Order Code)
The LR8450 and LR8450-01 cannot perform measurement on their own. One or more plug-in modules or wireless modules are required (sold separately). |
Sample output from a variety of sensors, including 1 ms pressure sensors Measures at a sampling rate of up to 1 ms. | |
Measure strain with a 1 ms sampling rate Connect strain gauges directly and measure at a sampling rate of up to 1 ms. | |
Measure temperature near an inverter or battery Example: strain measurement Measures at a sampling rate of up to 10 ms. | |
Make measurements in locations where it would be difficult to route wires With the LR8450-01 wireless LAN model and a wireless unit, you can streamline setup and minimize wire use by eliminating the need to run multiple long wires from the testing lab. | |
Observe data from remote locations on a computer The LR8450-01 wireless LAN model can connect to commercially available access points. By activating the LR8450-01’s station function and connecting to an access point, you can control the logger remotely via its HTTP server and acquire data via its FTP server. |
Max. number of connectable modules | 4 plug-in input modules + 7 wireless input modules *1 *1: LR8450-01 only |
---|---|
Connectable modules (Plug-in modules *2) | U8550, U8551, U8552, U8553, U8554 *2: Plug-in input modules can be connected to LR8450, LR8450-01 |
Connectable modules (Wireless modules *3) | LR8530, LR8531, LR8532, LR8533, LR8534 *3: The wireless input modules can be connected only to the LR8450-01. The wireless input modules will be supported by upgrading the main unit firmware. |
No. of measurement channels | Up to 120 ch with plug-in input modules, up to 330 ch with plug-in input modules and wireless input modules (wireless modules can be used only on LR8450-01) |
Pulse/logic input | [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval |
Recording intervals | 1 ms *5, 2 ms *5, 5 ms *5 (*5: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each unit |
Data storage | SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation) |
LAN interface | 100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software (Will be supported by version update), configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, NTP client, time synchronization with an NTP server |
Wireless LAN interface (LR8450-01 only) | IEEE 802.11b/g/n, Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES, Functions: Configuring settings and controlling recording using communications commands, FTP server / client, HTTP server, NTP client, Time synchronization with an NTP server |
USB interface | Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub)) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer |
SD card slot | SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: Z4001, Z4003 |
Display | 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel) |
Functions | Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable) |
Power supply | [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max. (Please contact your HIOKI distributor for connection cord) |
Dimensions and mass | Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D, 1108 g (39.1 oz) (excluding Battery Pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D |
Accessories | Quick Start Manual ×1, LOGGER Application Disk (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1, Precautions Concerning Use of Equipment that Emits Radio Waves (LR8450-01 only) ×1 |
Wireless certification | Japan, United States, Canada, Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey |
---|
Preview Catalog: MEMORY HiLOGGER LR8450 | Download PDF [2MB] | English |